Product Specifications

Standard

EN 1634-1

Isolation

110 kg/m3 Stone wool 30 mm, Fire-resistant drywall, (2 piece),128 kg/m3 Ceramic wool 6 mm

Fire Resistance

Class E: 120 min. – Class EI: 90 min.

Test Nr

557175

Case

2.0 mm GALVANIZED

Hinge

3 mm sheet metal bent hinges on each wing, two hinges, one self-springing

Leaf

1.0 mm GALVANIZED

Installation

Fire-resistant insulation materials are used in our installations. No mortar or filler is used.

Wing Thickness

65 mm